İçereği Atla

Multi-module CFBT Training Structure

Container-Based Training System Solution

Çok Modüllü CFBT Epitim Yapısı
Konteyner Tabanlı Eğitim Sistemi Çözümü


Overview of the Facility


  • This facility has been designed and designated as a training center by the IFIW (International Fire Instructors Organization). The overall design is aligned with European standards. The structure consists of five levels and includes 21 containers of various sizes.

  • CFBT (Compartment Fire Behavior Training) refers to training on fire and smoke behavior in indoor environments, firefighter hose stream application, ventilation and smoke extraction, and other fundamental aspects of firefighting operations.

  • Unlike traditional gas-fired training props, this container-based training structure uses wood as fuel, i.e., a dual Class A fire system. This allows the simulation of realistic Class A fire scenarios characterized by chaos, dense smoke, and complex environmental conditions, thereby increasing realism and enabling advanced training on real fire behavior.

​Tesis Hakkında Genel Bilgi

  • Bu tesis, IFIW (Uluslararası Yangın Eğitmenleri Organizasyonu) tarafından bir eğitim merkezi olarak tasarlanmış ve belirlenmiştir. Genel tasarım, Avrupa standartlarıyla uyumludur. Yapı beş seviyeden oluşur ve çeşitli boyutlarda 21 konteyner içerir.

  • CFBT (Kompartman Yangın Davranışı Eğitimi), kapalı alanlarda yangın ve duman davranışı eğitimi, itfaiyeci hortum uygulamaları, havalandırma ve duman tahliyesi ile diğer temel yangın söndürme operasyonlarını kapsar.

  • Geleneksel gazlı eğitim ekipmanlarının aksine, bu konteyner tabanlı eğitim yapısı yakıt olarak odun kullanır; yani çift Sınıf A yangın sistemi. Bu, kaotik, yoğun dumanlı ve karmaşık çevresel koşullara sahip gerçekçi Sınıf A yangın senaryolarının simülasyonuna imkan tanır. Bu sayede gerçek yangın davranışı üzerinde gelişmiş eğitim sağlanır.

Üstten Panoramik Görünüm

(Visual overview of the container structure from above)

Üstten Panoramik Görünüm

(Konteyner yapısının yukarıdan görsel genel bakışı)


Ground Floor Plan

Based on the international standard layout of CFBT training facilities.


By using Class A fire combustion chambers on both sides, the structure is divided into two training areas connected through typical building structures.

Key Areas:

  1. Class A fire containers 1, 2, and 3
  2. T-shaped attack corridor
  3. Backdraft / Flashover training room
  4. Staircases, elevator shaft, elevator anteroom, smoke-protected stair anteroom

The three training areas are interconnected by doors along the corridors, allowing combined training exercises or the creation of separate training courses.

Zemin Kat Planı

CFBT eğitim tesislerinin uluslararası standart düzenine dayanmaktadır.


Her iki tarafta Sınıf A yangın yakma odaları kullanılarak yapı, tipik bina yapıları ile bağlanan iki eğitim alanına ayrılmıştır.

Ana Alanlar:

  1. Sınıf A yangın konteynerleri 1, 2 ve 3
  2. T şeklinde saldırı koridoru
  3. Geri patlama / Ani alevlenme (Backdraft / Flashover) eğitim odası
  4. Merdivenler, asansör boşluğu, asansör antre odası, duman korumalı merdiven antre odası

Üç eğitim alanı, koridorlar boyunca kapılar ile birbirine bağlanmıştır; bu sayede birleşik eğitim egzersizleri veya ayrı eğitim kursları oluşturulabilir.


Birinci Kat Planı

The roof of the first level allows for top-down fire attack, simulating underground fire scenarios.

The second-level layout is dedicated to search and rescue training in a maze-like environment. Main training activities include:

  1. Rescue operations in smoke-filled environments
  2. Ventilation and smoke extraction training
  3. Underground fire scenarios
  4. Use of the fire service elevator

Smoke generated by the first-level combustion chambers is directed into the second-level training rooms through natural smoke movement or via the smoke evacuation system.

Inside the compartments, movable grid floor structures are installed. These can be flexibly combined to adjust the difficulty level of rescue operations and adapt training to firefighters with different experience levels.

Birinci Kat Planı

Birinci seviyenin çatısı, yer altı yangın senaryolarını simüle ederek yukarıdan aşağıya yangın saldırısına izin verir.

İkinci seviye düzeni, labirent benzeri bir ortamda arama ve kurtarma eğitimine ayrılmıştır. Ana eğitim faaliyetleri şunları içerir:

  1. Dumanla dolu ortamlarda kurtarma operasyonları
  2. Havalandırma ve duman tahliyesi eğitimi
  3. Yer altı yangın senaryoları
  4. İtfaiye asansörünün kullanımı

Birinci seviyedeki yanma odalarından çıkan duman, doğal duman hareketi veya duman tahliye sistemi aracılığıyla ikinci seviye eğitim odalarına yönlendirilir.

Kompartmanların içinde, taşınabilir ızgara taban yapıları kuruludur. Bu yapılar esnek bir şekilde birleştirilerek kurtarma operasyonlarının zorluk seviyesi ayarlanabilir ve farklı deneyim seviyelerindeki itfaiyecilere uygun eğitim sağlanabilir.