Se rendre au contenu

Multi-module CFBT Training Structure

Container-Based Training System Solution

Structure de formation CFBT multi-modules
Solution de Système de Formation Basé sur Conteneurs


Overview of the Facility


  • This facility has been designed and designated as a training center by the IFIW (International Fire Instructors Organization). The overall design is aligned with European standards. The structure consists of five levels and includes 21 containers of various sizes.

  • CFBT (Compartment Fire Behavior Training) refers to training on fire and smoke behavior in indoor environments, firefighter hose stream application, ventilation and smoke extraction, and other fundamental aspects of firefighting operations.

  • Unlike traditional gas-fired training props, this container-based training structure uses wood as fuel, i.e., a dual Class A fire system. This allows the simulation of realistic Class A fire scenarios characterized by chaos, dense smoke, and complex environmental conditions, thereby increasing realism and enabling advanced training on real fire behavior.

​Aperçu de l’Installation

  • Cette installation a été conçue et désignée comme centre de formation par l’IFIW (Organisation Internationale des Instructeurs de Sapeurs-Pompiers). La conception générale est conforme aux normes européennes. La structure comprend cinq niveaux et inclut 21 conteneurs de différentes tailles.

  • CFBT (Formation au Comportement du Feu en Compartiment) désigne la formation sur le comportement du feu et de la fumée en environnements intérieurs, l’utilisation des lances par les sapeurs-pompiers, la ventilation et l’extraction de fumée, ainsi que d’autres aspects fondamentaux des opérations de lutte contre l’incendie.
  • Contrairement aux dispositifs d’entraînement traditionnels alimentés au gaz, cette structure de formation basée sur des conteneurs utilise du bois comme combustible, c’est-à-dire un système d’incendie de Classe A double. Cela permet de simuler des scénarios d’incendie de Classe A réalistes, caractérisés par le chaos, une fumée dense et des conditions environnementales complexes, augmentant ainsi le réalisme et permettant une formation avancée sur le comportement réel du feu.​

Vue Panoramique Supérieure

(Visual overview of the container structure from above)

Vue Panoramique Supérieure

(Aperçu visuel de la structure des conteneurs vue d’en haut)


Ground Floor Plan

Based on the international standard layout of CFBT training facilities.


By using Class A fire combustion chambers on both sides, the structure is divided into two training areas connected through typical building structures.

Key Areas:

  1. Class A fire containers 1, 2, and 3
  2. T-shaped attack corridor
  3. Backdraft / Flashover training room
  4. Staircases, elevator shaft, elevator anteroom, smoke-protected stair anteroom

The three training areas are interconnected by doors along the corridors, allowing combined training exercises or the creation of separate training courses.

Plan du Rez-de-Chaussée

Basé sur la disposition standard internationale des installations de formation CFBT.

En utilisant des chambres de combustion pour incendies de Classe A des deux côtés, la structure est divisée en deux zones de formation reliées par des structures de bâtiment typiques.

Zones Clés:

  1. Conteneurs d’incendie de Classe A 1, 2 et 3
  2. Couloir d’attaque en forme de T
  3. Salle de formation Backdraft / Flashover
  4. Escaliers, cage d’ascenseur, antichambre de l’ascenseur, antichambre d’escalier protégée contre la fumée

Les trois zones de formation sont interconnectées par des portes le long des couloirs, permettant de réaliser des exercices de formation combinés ou de créer des parcours de formation distincts.


Plan du Premier Étage

The roof of the first level allows for top-down fire attack, simulating underground fire scenarios.

The second-level layout is dedicated to search and rescue training in a maze-like environment. Main training activities include:

  1. Rescue operations in smoke-filled environments
  2. Ventilation and smoke extraction training
  3. Underground fire scenarios
  4. Use of the fire service elevator

Smoke generated by the first-level combustion chambers is directed into the second-level training rooms through natural smoke movement or via the smoke evacuation system.

Inside the compartments, movable grid floor structures are installed. These can be flexibly combined to adjust the difficulty level of rescue operations and adapt training to firefighters with different experience levels.

Plan du Premier Étage

Le toit du premier niveau permet une attaque du feu par le haut, simulant des scénarios d’incendie souterrains.

La disposition du deuxième niveau est dédiée à la formation de recherche et sauvetage dans un environnement en forme de labyrinthe. Les principales activités de formation incluent :

  1. Opérations de sauvetage dans des environnements enfumés
  2. Formation à la ventilation et à l’extraction de fumée
  3. Scénarios d’incendie souterrains
  4. Utilisation de l’ascenseur des pompiers

La fumée générée par les chambres de combustion du premier niveau est dirigée vers les salles de formation du deuxième niveau par le mouvement naturel de la fumée ou via le système d’évacuation de fumée.

À l’intérieur des compartiments, des structures de plancher à grille mobiles sont installées. Celles-ci peuvent être combinées de manière flexible pour ajuster le niveau de difficulté des opérations de sauvetage et adapter la formation aux pompiers de différents niveaux d’expérience.



Second Floor Plan ​

Plan du Deuxième Étage




Third Floor Plan ​

Plan du Troisième Étage




Fourth Floor Plan ​

Plan du Quatrième Étage