Ir al contenido

Multi-module CFBT Training Structure

Container-Based Training System Solution

Estructura de formación CFBT multimódulo
Solución de Sistema de Entrenamiento Basado en Contenedores


Overview of the Facility


  • This facility has been designed and designated as a training center by the IFIW (International Fire Instructors Organization). The overall design is aligned with European standards. The structure consists of five levels and includes 21 containers of various sizes.

  • CFBT (Compartment Fire Behavior Training) refers to training on fire and smoke behavior in indoor environments, firefighter hose stream application, ventilation and smoke extraction, and other fundamental aspects of firefighting operations.

  • Unlike traditional gas-fired training props, this container-based training structure uses wood as fuel, i.e., a dual Class A fire system. This allows the simulation of realistic Class A fire scenarios characterized by chaos, dense smoke, and complex environmental conditions, thereby increasing realism and enabling advanced training on real fire behavior.

​Resumen de la Instalación

  • Esta instalación ha sido diseñada y designada como centro de formación por la IFIW (Organización Internacional de Instructores de Bomberos). El diseño general está alineado con los estándares europeos. La estructura consta de cinco niveles e incluye 21 contenedores de diversos tamaños.
  • CFBT (Entrenamiento en Comportamiento del Fuego en Compartimentos) se refiere a la formación sobre el comportamiento del fuego y el humo en entornos interiores, la aplicación de chorros de manguera por parte de los bomberos, la ventilación y extracción de humo, y otros aspectos fundamentales de las operaciones de extinción de incendios.

  • A diferencia de los elementos de entrenamiento tradicionales alimentados con gas, esta estructura de entrenamiento basada en contenedores utiliza madera como combustible, es decir, un sistema de incendio Clase A dual. Esto permite la simulación de escenarios de incendio Clase A realistas, caracterizados por el caos, humo denso y condiciones ambientales complejas, aumentando así el realismo y posibilitando un entrenamiento avanzado sobre el comportamiento real del fuego.

Vista Panorámica Superior

(Visual overview of the container structure from above)

Vista Panorámica Superior

(Vista general de la estructura de contenedores desde arriba)


Ground Floor Plan

Based on the international standard layout of CFBT training facilities.


By using Class A fire combustion chambers on both sides, the structure is divided into two training areas connected through typical building structures.

Key Areas:

  1. Class A fire containers 1, 2, and 3
  2. T-shaped attack corridor
  3. Backdraft / Flashover training room
  4. Staircases, elevator shaft, elevator anteroom, smoke-protected stair anteroom

The three training areas are interconnected by doors along the corridors, allowing combined training exercises or the creation of separate training courses.

Plano de Planta Baja

Basado en el diseño estándar internacional de las instalaciones de entrenamiento CFBT.

Al utilizar cámaras de combustión de incendios Clase A en ambos lados, la estructura se divide en dos áreas de entrenamiento conectadas mediante estructuras típicas de edificios.

Áreas Clave:

  1. Contenedores de incendio Clase A 1, 2 y 3
  2. Pasillo de ataque en forma de T
  3. Sala de entrenamiento de Backdraft / Flashover
  4. Escaleras, hueco de ascensor, antesala del ascensor, antesala de escalera protegida contra el humo

Las tres áreas de entrenamiento están interconectadas mediante puertas a lo largo de los pasillos, lo que permite realizar ejercicios de entrenamiento combinados o la creación de cursos de entrenamiento separados.


Plano del Primer Piso

The roof of the first level allows for top-down fire attack, simulating underground fire scenarios.

The second-level layout is dedicated to search and rescue training in a maze-like environment. Main training activities include:

  1. Rescue operations in smoke-filled environments
  2. Ventilation and smoke extraction training
  3. Underground fire scenarios
  4. Use of the fire service elevator

Smoke generated by the first-level combustion chambers is directed into the second-level training rooms through natural smoke movement or via the smoke evacuation system.

Inside the compartments, movable grid floor structures are installed. These can be flexibly combined to adjust the difficulty level of rescue operations and adapt training to firefighters with different experience levels.

Plano del Primer Piso

El techo del primer nivel permite un ataque al fuego desde arriba, simulando escenarios de incendios subterráneos.

El diseño del segundo nivel está dedicado al entrenamiento de búsqueda y rescate en un entorno tipo laberinto. Las principales actividades de entrenamiento incluyen:

  1. Operaciones de rescate en entornos llenos de humo
  2. Entrenamiento en ventilación y extracción de humo
  3. Escenarios de incendios subterráneos
  4. Uso del ascensor de bomberos

El humo generado por las cámaras de combustión del primer nivel se dirige a las salas de entrenamiento del segundo nivel mediante el movimiento natural del humo o a través del sistema de evacuación de humo.

Dentro de los compartimentos se instalan estructuras de suelo tipo rejilla móviles. Estas pueden combinarse de manera flexible para ajustar el nivel de dificultad de las operaciones de rescate y adaptar el entrenamiento a bomberos con distintos niveles de experiencia.



Second Floor Plan ​

Plano del Segundo Piso




Third Floor Plan ​

Plano del Tercer Piso




Fourth Floor Plan ​

Plano del Cuarto Piso